Por favor, use este identificador para citar o enlazar este ítem: http://www.monografias.ufop.br/handle/35400000/9713
Título : Metodologias de análise para controle de qualidade de cigarros eletrônicos.
Autor : Saraiva, Heitor de Pontes
metadata.dc.contributor.advisor: Paula, Camila Cristina Almeida de
metadata.dc.contributor.referee: Paula, Camila Cristina Almeida de
Santos, Mirian dos
Soares, Liliane Catone
Santo, Daiana Rocha do Espírito
Palabras clave : Vaporizadores
Aerossóis
Nicotina
Aromatizantes
GC-MS
Toxicologia
Fecha de publicación : 2026
Citación : SARAIVA, Heitor de Pontes. Metodologias de análise para controle de qualidade de cigarros eletrônicos. 2026. 42 f. Monografia (Graduação em Ciência e Tecnologia de Alimentos) - Escola de Nutrição, Universidade Federal de Ouro Preto, Ouro Preto, 2026.
Resumen : O consumo de cigarros eletrônicos (e-cigarettes ou vapes) apresenta uma expansão global acelerada, embora persista a ausência de padronização internacional e incertezas sobre a segurança química das formulações. Os e-liquids são matrizes complexas que utilizam solventes como propilenoglicol (PG) e glicerina vegetal (VG) para transportar nicotina e aromatizantes (flavours) como vanilina, cinamaldeído, benzaldeído e etil maltol. A preocupação central reside na segurança dessas substâncias via inalatória, uma vez que o aquecimento resistivo (frequentemente acima de 300°C) desencadeia a pirólise e oxidação térmica, gerando compostos carbonílicos tóxicos como formaldeído, acetaldeído e acroleína, além da liberação de metais das resistências, incluindo níquel (Ni), cromo (Cr), estanho (Sn) e chumbo (Pb). Diante desse cenário, este trabalho realizou uma análise bibliométrica abrangente utilizando a linguagem R e as bases Scopus e Web of Science, selecionando 152 artigos originais e de revisão publicados entre 2020 e 2026. Os indicadores revelaram um campo em franca expansão, com uma taxa de crescimento anual de 16,5% e uma média de 7,57 citações por documento. A produção científica é liderada por autores como Brown J (6 artigos), Jackson S, Shahab L e Bullen C (5 artigos cada), com forte concentração institucional na University of North Carolina (20 publicações), University of London e University of Auckland. Geograficamente, os EUA lideram com 473 citações, seguidos pelo Reino Unido (157) e Itália (124). A análise das metodologias evidenciou que a Cromatografia Gasosa acoplada à Espectrometria de Massas (GC-MS) é a técnica predominante para identificar voláteis e aromatizantes. A Cromatografia Líquida (LC-MS/MS) foi utilizado para a quantificação precisa de nicotina, alcaloides do tabaco, cafeína e contaminantes como PFAS. Para o monitoramento de metais como Al, Cu, Ni, Pb e Zn, a técnica de ICP-OES é o padrão ouro. Identificou-se ainda a ascensão de métodos de alta resolução (HRMS) para a descoberta de substâncias emergentes, como novos análogos de THC, e a aplicação de SERS (Raman) para dosagem rápida de nicotina. Como conclusão, o estudo evidencia uma heterogeneidade metodológica e a urgência de protocolos harmonizados para o controle de qualidade. Os resultados destacam que a aprovação de aromatizantes para uso alimentício não garante segurança inalatória, reforçando a necessidade de regulamentações mais estritas.
metadata.dc.description.abstracten: The consumption of electronic cigarettes (e-cigarettes or vapes) has expanded rapidly worldwide, despite the lack of international standardization and the persistent uncertainties regarding the chemical safety of their formulations. E-liquids are complex matrices composed of solvents such as propylene glycol (PG) and vegetable glycerin (VG), which serve as carriers for nicotine and flavoring compounds, including vanillin, cinnamaldehyde, benzaldehyde, and ethyl maltol. The primary concern lies in the safety of these substances when inhaled, as resistive heating (often exceeding 300°C) promotes pyrolysis and thermal oxidation, generating toxic carbonyl compounds such as formaldehyde, acetaldehyde, and acrolein, in addition to the release of metals from the heating coils, including nickel (Ni), chromium (Cr), tin (Sn), and lead (Pb). In this context, the present study conducted a comprehensive bibliometric analysis using the R programming language and data retrieved from the Scopus and Web of Science databases, selecting 152 original and review articles published between 2020 and 2025. The bibliometric indicators revealed a rapidly expanding research field, with an annual growth rate of 16.5% and an average of 7.57 citations per document. Scientific production was led by authors such as Brown J (six publications), Jackson S, Shahab L, and Bullen C (five publications each), with a strong institutional concentration at the University of North Carolina (20 publications), the University of London, and the University of Auckland. Geographically, the United States ranked first with 473 citations, followed by the United Kingdom (157) and Italy (124). The analysis of the analytical methodologies demonstrated that Gas Chromatography-Mass Spectrometry (GC-MS) is the predominant technique for the identification of volatile compounds and flavoring agents. Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) has become the essential technique for the accurate quantification of nicotine, tobacco alkaloids, caffeine, and contaminants such as per- and polyfluoroalkyl substances (PFAS). For the determination of metals such as Al, Cu, Ni, Pb, and Zn, Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) is considered the gold standard. The analysis also identified the increasing adoption of high-resolution mass spectrometry (HRMS) for the identification of emerging substances, including novel tetrahydrocannabinol (THC) analogs, as well as the application of Surface-Enhanced Raman Spectroscopy (SERS) for the rapid quantification of nicotine. In conclusion, this study provides a systematic overview of the current state of the art, highlighting the substantial methodological heterogeneity in the field and the urgent need for harmonized analytical protocols for quality control. The findings further demonstrate that the approval of flavoring agents for food applications does not ensure their safety for inhalation exposure, reinforcing the need for stricter regulatory frameworks and integrated research involving Analytical Chemistry, Toxicology, and Food Science.
URI : http://www.monografias.ufop.br/handle/35400000/9713
Aparece en las colecciones: Administração

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
MONOGRAFIA_MetodologiaAnaliseControle.pdf1,7 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.